Roll formed of 1/32" material
The equivalent rectangle for all conductors is 1" x 1/4". Supports are required at intervals of: 3' on curves, 3'-4" for lateral mount, 5' standard.

All roll-formed conductors are supplied assembled with connector pins and cover. Joint covers and joint keepers are furnished with each order as required.
Unit of Measure

Electrical Data

Ampacity (continuous duty)

N/A 350 A

Resistance R (for DC) at 20º C

N/A 60 µΩ/ft

Reactance X (60 Hz)

N/A 60 µΩ/ft

Impedance Z (60Hz)

N/A 84 µΩ/ft

Specifications

Material

N/A Rolled Copper

Cover Type

N/A Rigid PVC

Weight

N/A 3.5 lb0.76 lb/ft

Length

N/A 5 ft

Cross Sectional Area

N/A 0.1477 in²

Expansion Coefficient

N/A 0.000009 ºF

Support Spacing

N/A 5 ft

Normal Ambient

N/A -10 to 160 ºF