The Rowland Company
4900 North 20th Street
Philadelphia, PA 19144
Toll Free: 800-925-8824   Phone: 215-455-4900    Fax: 215-455-8888
E-Mail: rowland@rowland2.com    Web site: www.rowlandcompany.com
All Categories > Clutches and Brakes > Drum Clutches and Brakes > CB Clutches and Brakes > CB Elements and Mounting Components > Dual Flange CB Elements (Sizes 12 to 45) > Item # 142437  


Item # 142437, Dual Flange CB Elements (Sizes 12 to 45)


Two dual flanged elements can be bolted together to form a dual element having twice the torque capacity of a single element. Dual elements can be furnished in sizes 12CB350 through 45CB525.





Specifications  · Note

Specifications

Size

26CB525

Torque Rating (75 psi/5.5 bar)1

184800 lb·in
20900
Nm

Maximum Speed2

1050 rpm

Centrifugal Loss Constant Cs

2.35 E-06 bar/rpm2
34 E-06 psi/rpm2

Inertia

432 lb·ft²
18.14
kg·m²

Weight

272 lb
123
kg

Friction Area

808 in²
5212
cm²

New Friction Lining Thickness

0.33 in
8
mm

Worn Friction Lining Thickness

0.06 in
2
mm

Air Tube Cavity3

520 in³
8.53
dm³

Minimum Drum Diameter

25.81 in
656
mm

Dimension D2

14.25 in
362
mm

Dimension D25

0.25 in
6
mm

Dimension G4

34.000 in
863.6
mm

Dimension H2

32.750 in
831.9
mm

Dimension H6

26.19 in
665
mm

Dimension H7

32.50 in
826
mm

Number of Mounting Holes

16

Bolt Hole Size L

0.625 in
16
mm

Dimension O3

0.50 in
13
mm

Air Inlet Thread

1/2-14

Angle Q

11.250 º

Dimension V

0.84 in
21
mm

Number of Friction Shoes

32

Friction Shoe Width (W)

12.56 in
319
mm
1 Dynamic torque shown, static torque approximately 25% greater. Torque in each application is dependent upon air pressure and speed.
2 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
3 Drum contact with worn shoes.
4 Tolerance for sizes:
12 thru 24, 28 and 32
+0.000/-0.005 in (+0.00/-0.13 mm)
26 and 30
+0.000/-0.008 in (+0.00/-0.20 mm)
36 thru 45
+0.000/-0.010 in (+0.00/-0.25 mm)


Note
Refers to basic part number only. When ordering, the number of air inlets and type of connection must be specified.