The Rowland Company
4900 North 20th Street
Philadelphia, PA 19144
Toll Free: 800-925-8824   Phone: 215-455-4900    Fax: 215-455-8888
E-Mail: rowland@rowland2.com    Web site: www.rowlandcompany.com
All Categories > Clutches and Brakes > Drum Clutches and Brakes > CB Clutches and Brakes > CB Elements and Mounting Components > Dual Flange CB Elements (Sizes 12 to 45) > Item # 142438  


Item # 142438, Dual Flange CB Elements (Sizes 12 to 45)


Two dual flanged elements can be bolted together to form a dual element having twice the torque capacity of a single element. Dual elements can be furnished in sizes 12CB350 through 45CB525.





Specifications  · Note

Specifications

Size

28CB525

Torque Rating (75 psi/5.5 bar)1

212000 lb·in
24000
Nm

Maximum Speed2

1000 rpm

Centrifugal Loss Constant Cs

2.55 E-06 bar/rpm2
37 E-06 psi/rpm2

Inertia

517 lb·ft²
21.71
kg·m²

Weight

286 lb
130
kg

Friction Area

860 in²
5547
cm²

New Friction Lining Thickness

0.33 in
8
mm

Worn Friction Lining Thickness

0.06 in
2
mm

Air Tube Cavity3

560 in³
9.18
dm³

Minimum Drum Diameter

27.81 in
706
mm

Dimension D2

14.44 in
367
mm

Dimension D25

0.25 in
6
mm

Dimension G4

36.000 in
914.4
mm

Dimension H2

34.750 in
882.7
mm

Dimension H6

28.19 in
716
mm

Dimension H7

34.50 in
876
mm

Number of Mounting Holes

16

Bolt Hole Size L

0.625 in
16
mm

Dimension O3

0.50 in
13
mm

Air Inlet Thread

1/2-14

Angle Q

11.250 º

Dimension V

0.84 in
21
mm

Number of Friction Shoes

34

Friction Shoe Width (W)

12.69 in
322
mm
1 Dynamic torque shown, static torque approximately 25% greater. Torque in each application is dependent upon air pressure and speed.
2 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
3 Drum contact with worn shoes.
4 Tolerance for sizes:
12 thru 24, 28 and 32
+0.000/-0.005 in (+0.00/-0.13 mm)
26 and 30
+0.000/-0.008 in (+0.00/-0.20 mm)
36 thru 45
+0.000/-0.010 in (+0.00/-0.25 mm)


Note
Refers to basic part number only. When ordering, the number of air inlets and type of connection must be specified.