The Rowland Company
4900 North 20th Street
Philadelphia, PA 19144
Toll Free: 800-925-8824   Phone: 215-455-4900    Fax: 215-455-8888
E-Mail: rowland@rowland2.com    Web site: www.rowlandcompany.com
All Categories > Clutches and Brakes > Drum Clutches and Brakes > CB Clutches and Brakes > CB Elements and Mounting Components > Dual Flange CB Elements (Sizes 12 to 45) > Item # 142731  


Item # 142731, Dual Flange CB Elements (Sizes 12 to 45)


Two dual flanged elements can be bolted together to form a dual element having twice the torque capacity of a single element. Dual elements can be furnished in sizes 12CB350 through 45CB525.





Specifications  · Note

Specifications

Size

12CB350

Torque Rating (75 psi/5.5 bar)1

26600 lb·in
3010
Nm

Maximum Speed2

1800 rpm

Centrifugal Loss Constant Cs

0.83 E-06 bar/rpm2
12 E-06 psi/rpm2

Inertia

25 lb·ft²
1.05
kg·m²

Weight

62 lb
28
kg

Friction Area

256 in²
1651
cm²

New Friction Lining Thickness

0.20 in
5
mm

Worn Friction Lining Thickness

0.06 in
2
mm

Air Tube Cavity3

160 in³
2.62
dm³

Minimum Drum Diameter

11.9 in
302
mm

Dimension D2

10.13 in
257
mm

Dimension D25

0.19 in
5
mm

Dimension G4

17.625 in
447.7
mm

Dimension H2

16.875 in
428.6
mm

Dimension H6

12.13 in
308
mm

Dimension H7

16.88 in
429
mm

Number of Mounting Holes

14

Bolt Hole Size L

0.375 in
10
mm

Dimension O3

0.31 in
8
mm

Air Inlet Thread

3/8-18

Angle Q

12.857 º

Dimension V

0.69 in
17
mm

Number of Friction Shoes

24

Friction Shoe Width (W)

8.75 in
222
mm
1 Dynamic torque shown, static torque approximately 25% greater. Torque in each application is dependent upon air pressure and speed.
2 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
3 Drum contact with worn shoes.
4 Tolerance for sizes:
12 thru 24, 28 and 32
+0.000/-0.005 in (+0.00/-0.13 mm)
26 and 30
+0.000/-0.008 in (+0.00/-0.20 mm)
36 thru 45
+0.000/-0.010 in (+0.00/-0.25 mm)


Note
Refers to basic part number only. When ordering, the number of air inlets and type of connection must be specified.