The Rowland Company
4900 North 20th Street
Philadelphia, PA 19144
Toll Free: 800-925-8824   Phone: 215-455-4900    Fax: 215-455-8888
E-Mail: rowland@rowland2.com    Web site: www.rowlandcompany.com
All Categories > Crane Control & Electrification > Crane Control & Electrification-Accessories > Cellular Buffers > Lift Buffers with Steel Plate > Item # 018230-165x160  


Item # 018230-165x160, Lift Buffers with Steel Plate


The design check for the lift buffers listed in the table has been made according to the hoisting directives 95/16/EG. The permissible load zones are documented for each lift buffer type by the certificate No. An EC design check certificate can be provided for each lift buffer type.
Lifts with lower speed than the maximum nominal speed taken as a basis for the design check, are for the same load zone, when the loads from cabin / working load or counter load are within the values mmax and mmin.






Specifications  · Note

Specifications

Maximum Permissible Impact Mass @ 0.4 m/s

3434 kg

Minimum Permissible Impact Mass @ 0.4 m/s

278 kg

Maximum Permissible Impact Mass @ 0.63 m/s

3117 kg

Minimum Permissible Impact Mass @ 0.63 m/s

395 kg

Maximum Permissible Impact Mass @ 1.00m/s

3035 kg

Minimum Permissible Impact Mass @ 1.00m/s

465 kg

Maximum Comp. Length

144 mm

Dimension G

3.4 kg

Dimension d1

165 mm

Dimension h1

160 mm

Dimension S

10 mm

PE1

1 pc
1 1)= packing unit = minimum order quantity


Note
Tolerances of the cellular buffers according to ISO 3302-1M4