The Rowland Company
4900 North 20th Street
Philadelphia, PA 19144
Toll Free: 800-925-8824   Phone: 215-455-4900    Fax: 215-455-8888
E-Mail: rowland@rowland2.com    Web site: www.rowlandcompany.com
All Categories > Crane Control & Electrification > Conductor Bar Systems > Hevi-Bar II Conductor Bar > Conductor Bars > Standard Conductor Bar for Hevi-Bar II Conductor Bar > Item # 32496  


Item # 32496, Standard Conductor Bar for Hevi-Bar II Conductor Bar






Specifications  · Cover Specifications

Specifications

Amperage Rating

500 A

Material

Polycarbonate

Maximum Temperature

250 ºF

Cover Type

Phase & Ground/ Indoors & Outdoors (Red)

Weight

25.0 lb

Length

30.0 ft

Cross Sectional Area

0.45 in²

Maximum System Voltage AC or DC (Per UL Listing)

View
600 V

Resistance R (for DC) at 20º C

3.27 x 10-5 c/ft

Phase Corrected Impedance Z at 20º C

5.40 x 10-5 c/ft

Support Spacing

5 ft

Spacing between Conductors

3.0 in

Minimum Bending Radius

8 ft

Available Accessories

Pick-up Guides for discontinuous systems
Thermostatically controlled heater wire system, for ice and snow environments

Transfer Caps for switches

Vertical and horizontal curves

Corrosion Protection Option

Stainless Steel
Zinc Plated


Cover Specifications

Normal Ambient

-40 to 200 ºF

Dielectric Strength

600 V/mil

Volume Resistivity

>1013 Ω/mil

Flame Test

Self Extinguishing

Specific Density

1.15 g/cm³