The Rowland Company
4900 North 20th Street
Philadelphia, PA 19144
Toll Free: 800-925-8824   Phone: 215-455-4900    Fax: 215-455-8888
E-Mail: rowland@rowland2.com    Web site: www.rowlandcompany.com
All Categories > Crane Control & Electrification > Conductor Bar Systems > Hevi-Bar II Conductor Bar > Conductor Bars > DURA-COAT Conductor Bar with Splice Installed > Item # 39745-J  


Item # 39745-J, DURA-COAT Conductor Bar with Splice Installed


For highly corrosive environments





Specifications  · Cover Specifications

Specifications

Amperage Rating

500 A

Material

PVC

Maximum Temperature

160 ºF

Cover Type

Phase / Indoors (Orange)

Weight

25.0 lb

Length

30.0 ft

Cross Sectional Area

0.45 in²

Maximum System Voltage AC or DC (Per UL Listing)

View
600 V

Resistance R (for DC) at 20º C

3.27 x 10-5 c/ft

Phase Corrected Impedance Z at 20º C

5.40 x 10-5 c/ft

Support Spacing

5 ft

Spacing between Conductors

3.0 in

Minimum Bending Radius

8 ft

Available Accessories

Pick-up Guides for discontinuous systems
Thermostatically controlled heater wire system, for ice and snow environments

Transfer Caps for switches

Vertical and horizontal curves


Cover Specifications

Normal Ambient

-40 to 104 ºF

Dielectric Strength

450 V/mil

Volume Resistivity

>1012 Ω/mil

Flame Test

Self Extinguishing

Specific Density

1.5 g/cm³