Assembly Number
|
|
7-308-110-100-0
|
|
Dynamic Torque Rating (80 psi/5.5 bar)1
|
|
4320 lb.in 479 Nm
|
|
Dynamic Torque Rating (100 psi/7 bar)2
|
|
5400 lb.in 610 Nm
|
|
Heat Capacity for Series Water Hosing
|
|
21 hp 16 kW
|
|
Heat Capacity for Parallel Water Hosing
|
|
32 hp 24 kW
|
|
Maximum Bore Size
|
|
2.25 in 57 mm
|
|
Parallel Water Flow 0 % Ethylene Glycol
|
|
3.2 gpm 12 lpm
|
|
Parallel Water Flow 30 % Ethylene Glycol
|
|
4.1 gpm 1.6 lpm
|
|
Parallel Water Flow 50 % Ethylene Glycol
|
|
5 gpm 19 lpm
|
|
Total Brake (Weight)
|
|
68 lb 30.8 kg
|
|
Disc & Gear (Weight)
|
|
11 lb 5 kg
|
|
Disc & Gear (Inertia)
|
|
0.6 lb·ft² 0.03 kg·m²
|
|
Pressure Drop Series Flow with 0 % Ethylene Glycol
|
|
4 psi 0.14 bar
|
|
Pressure Drop Series Flow with 30 % Ethylene Glycol
|
|
9 psi 0.62 bar
|
|
Pressure Drop Series Flow with 50 % Ethylene Glycol
|
|
9 psi 0.62 bar
|
|
Maximum Lining Wear
|
|
0.4 in 1.0 cm 10 in³ 0.2 dm³
|
|
Water Volume
|
|
8 in³ 0.13 dm³
|
|
Pilot Diameter A
|
|
12.125/12.128 in 307.98/308.05 mm
|
|
Bolt Hole Circle Diameter B
|
|
11.125 in 282.58 mm
|
|
Pilot Diameter C
|
|
8.375/8.378 in 212.73/212.80 mm
|
|
Dimension D
|
|
11.75 in 288.5 mm
|
|
Dimension F
|
|
2.00 in 50.8 mm
|
|
Dimension G
|
|
1.13 in 28.7 mm
|
|
Dimension H
|
|
5.68 in 144.3 mm
|
|
Dimension J
|
|
0.25 in 6.4 mm
|
|
Number of Bolt Holes
|
|
4
|
|
Bolt Hole Size L
|
|
17/32 in 13.5 mm
|
|
Dimension M
|
|
4.38 in 111.3 mm
|
|
Dimension N
|
|
3.50 in 88.9 mm
|
|
Dimension Q
|
|
1.38 in 35.1 mm
|
|
Number of Inlet Ports - Thread Size
|
|
2- 1/2 NPT
|
|
Dimension T
|
|
3.75 in 95.3 mm
|
|
Minimum U
|
|
1.00 in 25.4 mm
|
|
Maximum U
|
|
2.25 in 57.2 mm
|
|
Number of Coolant Inlets - Thread Size3
|
|
2 - 3/8 NPT
|
|
Manufacturer
|
|
Wichita Clutch
|
|
Actuation
|
|
Air Applied
|
|
1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
3 Number of inlets and outlets are equivalent. (Consult factory for drawing before final layout.)
|
|