Assembly Number
|
|
7-314-110-115-0
|
|
Dynamic Torque Rating (80 psi/5.5 bar)1
|
|
16800 lb.in 1864 Nm
|
|
Dynamic Torque Rating (100 psi/7 bar)2
|
|
21000 lb.in 2373 Nm
|
|
Heat Capacity for Series Water Hosing
|
|
50 hp 37 kW
|
|
Heat Capacity for Parallel Water Hosing
|
|
75 hp 56 kW
|
|
Maximum Bore Size
|
|
4.38 in 111 mm
|
|
Parallel Water Flow 0 % Ethylene Glycol
|
|
7.5 gpm 28 lpm
|
|
Parallel Water Flow 30 % Ethylene Glycol
|
|
9.8 gpm 37 lpm
|
|
Parallel Water Flow 50 % Ethylene Glycol
|
|
12 gpm 45 lpm
|
|
Total Brake (Weight)
|
|
221 lb 100.2 kg
|
|
Disc & Gear (Weight)
|
|
40 lb 18 kg
|
|
Disc & Gear (Inertia)
|
|
5 lb·ft² 0.21 kg·m²
|
|
Pressure Drop Series Flow with 0 % Ethylene Glycol
|
|
4 psi 0.14 bar
|
|
Pressure Drop Series Flow with 30 % Ethylene Glycol
|
|
8 psi 0.55 bar
|
|
Pressure Drop Series Flow with 50 % Ethylene Glycol
|
|
12 psi 0.83 bar
|
|
Maximum Lining Wear
|
|
0.5 in 1.3 cm 60 in³ 1.0 dm³
|
|
Water Volume
|
|
20 in³ 0.33 dm³
|
|
Pilot Diameter A
|
|
18.747/18.750 in 476.17/476.25 mm
|
|
Bolt Hole Circle Diameter B
|
|
17.500 in 444.50 mm
|
|
Pilot Diameter C
|
|
14.375/14.378 in 365.13/365.20 mm
|
|
Dimension D
|
|
17.50 in 444.5 mm
|
|
Dimension F
|
|
3.25 in 82.6 mm
|
|
Dimension G
|
|
1.06 in 26.9 mm
|
|
Dimension H
|
|
7.00 in 177.8 mm
|
|
Dimension J
|
|
0.25 in 6.4 mm
|
|
Number of Bolt Holes
|
|
6
|
|
Bolt Hole Size L
|
|
21/32 in 16.7 mm
|
|
Dimension M
|
|
7.38 in 187.5 mm
|
|
Dimension N
|
|
6.50 in 165.1 mm
|
|
Dimension Q
|
|
1.50 in 38.1 mm
|
|
Number of Inlet Ports - Thread Size
|
|
2- 1/2 NPT
|
|
Dimension T
|
|
7.00 in 177.8 mm
|
|
Minimum U
|
|
1.38 in 35.1 mm
|
|
Maximum U
|
|
4.38 in 111.3 mm
|
|
Number of Coolant Inlets - Thread Size3
|
|
2 - 1/2 NPT
|
|
Manufacturer
|
|
Wichita Clutch
|
|
Actuation
|
|
Air Applied
|
|
1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
3 Number of inlets and outlets are equivalent. (Consult factory for drawing before final layout.)
|
|