Assembly Number
|
|
7-318-110-100-0
|
|
Dynamic Torque Rating (80 psi/5.5 bar)1
|
|
37600 lb.in 4172 Nm
|
|
Dynamic Torque Rating (100 psi/7 bar)2
|
|
47000 lb.in 5310 Nm
|
|
Heat Capacity for Series Water Hosing
|
|
80 hp 60 kW
|
|
Heat Capacity for Parallel Water Hosing
|
|
120 hp 89 kW
|
|
Maximum Bore Size
|
|
5.50 in 140 mm
|
|
Parallel Water Flow 0 % Ethylene Glycol
|
|
12 gpm 45 lpm
|
|
Parallel Water Flow 30 % Ethylene Glycol
|
|
16 gpm 60 lpm
|
|
Parallel Water Flow 50 % Ethylene Glycol
|
|
19 gpm 72 lpm
|
|
Total Brake (Weight)
|
|
415 lb 188 kg
|
|
Disc & Gear (Weight)
|
|
88 lb 39.9 kg
|
|
Disc & Gear (Inertia)
|
|
18 lb·ft² 0.76 kg·m²
|
|
Pressure Drop Series Flow with 0 % Ethylene Glycol
|
|
7 psi 0.48 bar
|
|
Pressure Drop Series Flow with 30 % Ethylene Glycol
|
|
13 psi 0.9 bar
|
|
Pressure Drop Series Flow with 50 % Ethylene Glycol
|
|
20 psi 1.38 bar
|
|
Maximum Lining Wear
|
|
0.6 in 1.5 cm 75 in³ 1.2 dm³
|
|
Water Volume
|
|
48 in³ 0.8 dm³
|
|
Pilot Diameter A
|
|
23.247/23.250 in 590.47/590.55 mm
|
|
Bolt Hole Circle Diameter B
|
|
22.000 in 558.80 mm
|
|
Pilot Diameter C
|
|
18.250/18.253 in 463.55/463.63 mm
|
|
Dimension D
|
|
21.88 in 555.8 mm
|
|
Dimension F
|
|
3.63 in 921.2 mm
|
|
Dimension G
|
|
1.06 in 26.9 mm
|
|
Dimension H
|
|
8.00 in 203.2 mm
|
|
Dimension J
|
|
0.25 in 6.4 mm
|
|
Number of Bolt Holes
|
|
10
|
|
Bolt Hole Size L
|
|
21/32 in 16.7 mm
|
|
Dimension M
|
|
9.38 in 238.3 mm
|
|
Dimension N
|
|
8.25 in 209.6 mm
|
|
Dimension Q
|
|
1.50 in 38.1 mm
|
|
Number of Inlet Ports - Thread Size
|
|
3- 1/2 NPT
|
|
Dimension T
|
|
9.75 in 247.7 mm
|
|
Minimum U
|
|
2.00 in 50.8 mm
|
|
Maximum U
|
|
5.50 in 139.7 mm
|
|
Number of Coolant Inlets - Thread Size3
|
|
2 - 1/2 NPT
|
|
Manufacturer
|
|
Wichita Clutch
|
|
Actuation
|
|
Air Applied
|
|
1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
3 Number of inlets and outlets are equivalent. (Consult factory for drawing before final layout.)
|
|