Assembly Number
|
|
7-325-110-100-0
|
|
Dynamic Torque Rating (80 psi/5.5 bar)1
|
|
100800 lb.in 11185 Nm
|
|
Dynamic Torque Rating (100 psi/7 bar)2
|
|
126000 lb.in 14236 Nm
|
|
Heat Capacity for Series Water Hosing
|
|
190 hp 142 kW
|
|
Heat Capacity for Parallel Water Hosing
|
|
285 hp 213 kW
|
|
Maximum Bore Size
|
|
7.63 in 194 mm
|
|
Parallel Water Flow 0 % Ethylene Glycol
|
|
29 gpm 106 lpm
|
|
Parallel Water Flow 30 % Ethylene Glycol
|
|
38 gpm 144 lpm
|
|
Parallel Water Flow 50 % Ethylene Glycol
|
|
45 gpm 170 lpm
|
|
Total Brake (Weight)
|
|
935 lb 424 kg
|
|
Disc & Gear (Weight)
|
|
240 lb 109 kg
|
|
Disc & Gear (Inertia)
|
|
110 lb·ft² 4.64 kg·m²
|
|
Pressure Drop Series Flow with 0 % Ethylene Glycol
|
|
7 psi 0.48 bar
|
|
Pressure Drop Series Flow with 30 % Ethylene Glycol
|
|
11 psi 0.76 bar
|
|
Pressure Drop Series Flow with 50 % Ethylene Glycol
|
|
14 psi 0.97 bar
|
|
Maximum Lining Wear
|
|
0.8 in 2.0 cm 200 in³ 3.3 dm³
|
|
Water Volume
|
|
110 in³ 1.8 dm³
|
|
Pilot Diameter A
|
|
29.997/30.000 in 761.9/762.0 mm
|
|
Bolt Hole Circle Diameter B
|
|
28.750 in 730.250 mm
|
|
Pilot Diameter C
|
|
24.378/24.375 in 619.13/619.20 mm
|
|
Dimension D
|
|
31.00 in 787.4 mm
|
|
Dimension F
|
|
5.00 in 127 mm
|
|
Dimension G
|
|
1.38 in 35.1 mm
|
|
Dimension H
|
|
9.79 in 248.7 mm
|
|
Dimension J
|
|
0.25 in 6.4 mm
|
|
Number of Bolt Holes
|
|
10
|
|
Bolt Hole Size L
|
|
21/32 in 16.7 mm
|
|
Dimension M
|
|
12.69 in 322.3 mm
|
|
Dimension N
|
|
11.50 in 292.1 mm
|
|
Dimension Q
|
|
0.94 in 23.9 mm
|
|
Number of Inlet Ports - Thread Size
|
|
3- 1/2 NPT
|
|
Dimension T
|
|
15.12 in 384.0 mm
|
|
Minimum U
|
|
2.00 in 50.8 mm
|
|
Maximum U
|
|
7.63 in 193.8 mm
|
|
Number of Coolant Inlets - Thread Size3
|
|
2 - 1 NPT
|
|
Manufacturer
|
|
Wichita Clutch
|
|
Actuation
|
|
Air Applied
|
|
1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
3 Number of inlets and outlets are equivalent. (Consult factory for drawing before final layout.)
|
|