- Copper disc design for high heat dissipation
- Accurate control
Engagement is achieved by pneumatic expansion of the airtube. This air-operated clutch contains copper discs for excellent heat dissipation and provides an accurately controlled continuous slip action for constant web tensioning. Tension levels are in direct proportion to air pressure applied.
Unit of Measure
Design Features
N/A
|
Specifications
Assembly Number |
N/A 7-306-110-200-0 |
Dynamic Torque Rating (80 psi/5.5 bar)1 | N/A 2720 lb.in 307 Nm |
Dynamic Torque Rating (100 psi/7 bar)2 | N/A 3400 lb.in 384 Nm |
Heat Capacity for Series Water Hosing |
N/A 10 hp7.5 kW |
Heat Capacity for Parallel Water Hosing |
N/A 15 hp11 kW |
Maximum Bore Size |
N/A 1.75 in44 mm |
Parallel Water Flow 0 % Ethylene Glycol |
N/A 1.5 gpm6 lpm |
Parallel Water Flow 30 % Ethylene Glycol |
N/A 2.0 gpm7.4 lpm |
Parallel Water Flow 50 % Ethylene Glycol |
N/A 2.3 gpm8.5 lpm |
Total Brake (Weight) |
N/A 45 lb20.4 kg |
Disc & Gear (Weight) |
N/A 5.5 lb2.5 kg |
Disc & Gear (Inertia) |
N/A 0.14 lb·ft²0.01 kg·m² |
Pilot Diameter A |
N/A 8.751/8.753 in222.28/222.33 mm |
Bolt Hole Circle Diameter B |
N/A 8.000 in203.20 mm |
Pilot Diameter C |
N/A 7.377/7.379 in187.38/187.43 mm |
Dimension D |
N/A 8.81 in223.8 mm |
Dimension F |
N/A 2.00 in50.8 mm |
Dimension G |
N/A 0.75 in19.1 mm |
Dimension H |
N/A 5.25 in133.4 mm |
Dimension J |
N/A 0.13 in3.3 mm |
Number of Bolt Holes |
N/A 4 |
Bolt Hole Size L |
N/A 0.34 in8.6 mm |
Dimension M |
N/A 2.94 in74.7 mm |
Dimension N |
N/A 2.43 in61.7 mm |
Dimension Q |
N/A 0.38 in9.7 mm |
Number of Inlet Ports - Thread Size |
N/A 2- 1/2 NPT |
Dimension T |
N/A 2.00 in50.8 mm |
Minimum U |
N/A 0.60 in15.2 mm |
Maximum U |
N/A 1.75 in44.5 mm |
Number of Coolant Inlets - Thread Size3 | N/A 2 - 1/4 NPT |
Manufacturer |
N/A Wichita Clutch |
Actuation |
N/A Air Applied |
- 1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
- 2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
-
3 Number of inlets and outlets are equivalent.