- Copper disc design for high heat dissipation
- Accurate control
Engagement is achieved by pneumatic expansion of the airtube. This air-operated clutch contains copper discs for excellent heat dissipation and provides an accurately controlled continuous slip action for constant web tensioning. Tension levels are in direct proportion to air pressure applied.
Design Features
N/A
|
Specifications
Assembly Number |
N/A 7-326-100-100-0 |
Dynamic Torque Rating (80 psi/5.5 bar)1 | N/A 122920 lb.in 13880 Nm |
Dynamic Torque Rating (100 psi/7 bar)2 | N/A 153650 lb.in 17360 Nm |
Heat Capacity for Parallel Water Hosing |
N/A 350 hp261 kW |
Maximum Bore Size |
N/A 8.13 in207 mm |
Parallel Water Flow 0 % Ethylene Glycol |
N/A 35 gpm132 lpm |
Parallel Water Flow 30 % Ethylene Glycol |
N/A 45 gpm170 lpm |
Parallel Water Flow 50 % Ethylene Glycol |
N/A 54 gpm204 lpm |
Total Brake (Weight) |
N/A 886 lb402 kg |
Pilot Diameter A |
N/A 32.75 in831.9 mm |
Bolt Hole Circle Diameter B |
N/A 28.750 in730.25 mm |
Pilot Diameter C |
N/A 24.375/24.378 in619.20/619.13 mm |
Dimension D |
N/A 32.75 in831.9 mm |
Dimension F |
N/A 5.00 in127 mm |
Dimension G |
N/A 2.36 in59.9 mm |
Dimension H |
N/A 11.00 in279 mm |
Dimension J |
N/A 0.25 in6.4 mm |
Number of Bolt Holes |
N/A 12 |
Bolt Hole Size L |
N/A 21/32 in16.7 mm |
Dimension M |
N/A 15.50 in393.7 mm |
Dimension N |
N/A 11.67 in296.4 mm |
Dimension Q |
N/A 2.00 in50.8 mm |
Number of Inlet Ports - Thread Size |
N/A 4- 1/2 NPT |
Dimension T |
N/A 12.00 in304.8 mm |
Minimum U |
N/A 4.00 in102 mm |
Maximum U |
N/A 207 mm |
Number of Coolant Inlets - Thread Size3 | N/A 2 - 1.25 NPT |
Manufacturer |
N/A Wichita Clutch |
Actuation |
N/A Air Applied |
Note
N/A
Maximum water jacket inlet pressure is 60 PSI. Brakes with as great as 50 % higher torque capacity is available upon request. |
- 1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
- 2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
-
3 Number of inlets and outlets are equivalent.
(Consult factory for drawing before final layout.)