- Copper disc design for high heat dissipation
- Accurate control
Engagement is achieved by pneumatic expansion of the airtube. This air-operated clutch contains copper discs for excellent heat dissipation and provides an accurately controlled continuous slip action for constant web tensioning. Tension levels are in direct proportion to air pressure applied.
Unit of Measure
Design Features
N/A
|
Specifications
Assembly Number |
N/A 7-311-310-100-0 |
Dynamic Torque Rating (80 psi/5.5 bar)1 | N/A 28800 lb.in 3196 Nm |
Dynamic Torque Rating (100 psi/7 bar)2 | N/A 36000 lb.in 4067 Nm |
Heat Capacity for Series Water Hosing |
N/A 105 hp78 kW |
Heat Capacity for Parallel Water Hosing |
N/A 158 hp118 kW |
Maximum Bore Size |
N/A 3.00 in76 mm |
Parallel Water Flow 0 % Ethylene Glycol |
N/A 15.8 gpm60 lpm |
Parallel Water Flow 30 % Ethylene Glycol |
N/A 20.5 gpm78 lpm |
Parallel Water Flow 50 % Ethylene Glycol |
N/A 20.5 gpm78 lpm |
Total Brake (Weight) |
N/A 314 lb142.4 kg |
Disc & Gear (Weight) |
N/A 84 lb38.1 kg |
Disc & Gear (Inertia) |
N/A 6 lb·ft²0.25 kg·m² |
Pilot Diameter A |
N/A 15.997/16.000 in406.32/406.40 mm |
Bolt Hole Circle Diameter B |
N/A 14.75 in374.65 mm |
Pilot Diameter C |
N/A 11.375/11.378 in288.93/289.00 mm |
Dimension D |
N/A 14.75 in374.7 mm |
Dimension F |
N/A 9.12 in231.6 mm |
Dimension G |
N/A 0.75 in19.1 mm |
Dimension H |
N/A 12.81 in325.4 mm |
Dimension J |
N/A 0.25 in6.4 mm |
Number of Bolt Holes |
N/A 4 |
Bolt Hole Size L |
N/A 21/32 in16.7 mm |
Dimension M |
N/A 5.38 in136.7 mm |
Dimension N |
N/A 4.63 in117.6 mm |
Dimension Q |
N/A 1.13 in28.7 mm |
Number of Inlet Ports - Thread Size |
N/A 2- 1/2 NPT |
Dimension T |
N/A 5.25 in133.4 mm |
Minimum U |
N/A 1.00 in25.4 mm |
Maximum U |
N/A 3.00 in76.2 mm |
Number of Coolant Inlets - Thread Size3 | N/A 4 - 1/2 NPT |
Manufacturer |
N/A Wichita Clutch |
Actuation |
N/A Air Applied |
- 1 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
- 2 Static torque will vary with temperature. Maximum air pressure is 100 PSI / 7 BAR. Minimum recommended air pressure is 3 PSI.
-
3 Number of inlets and outlets are equivalent.