Roll formed of 1/32" material
The equivalent rectangle for all conductors is 1" x 1/4". Supports are required at intervals of: 3' on curves, 3'-4" for lateral mount, 5' standard.

All roll-formed conductors are supplied assembled with connector pins and cover. Joint covers and joint keepers are furnished with each order as required.
Unit of Measure

Electrical Data

Ampacity (continuous duty)

350 A

Resistance R (for DC) at 20º C

60 µΩ/ft

Reactance X (60 Hz)

60 µΩ/ft

Impedance Z (60Hz)

84 µΩ/ft

Specifications

Material

Rolled Copper

Cover Type

Rigid PVC

Weight

7.0 lb0.76 lb/ft

Length

10 ft

Cross Sectional Area

0.1477 in²

Expansion Coefficient

0.000009 ºF

Support Spacing

5 ft

Normal Ambient

-10 to 160 ºF