Print Back
for highly corrosive environments
Hevi dura-Bar500A
Hevi conductor-Bar500Adim
Unit of Measure
Items Hevi dura-Bar500A
39747-J
DURA-COAT Conductor Bar Cut Lengths with Splice Installed
Hevi dura-Bar500A
51861-J
DURA-COAT Conductor Bar Cut Lengths with Splice Installed
Hevi dura-Bar500A
51367-J
DURA-COAT Conductor Bar Cut Lengths with Splice Installed
Hevi dura-Bar500A
51383-J
DURA-COAT Conductor Bar Cut Lengths with Splice Installed
Hevi dura-Bar700A
51372-J
DURA-COAT Conductor Bar Cut Lengths with Splice Installed
Amperage Rating N/A 500 A N/A 500 A N/A 500 A N/A 500 A N/A 700 A
Material N/A PVC N/A PVC N/A PVC N/A Polycarbonate N/A PVC
Maximum Temperature N/A 160 ºF N/A 160 ºF N/A 160 ºF N/A 250 ºF N/A 160 ºF
Cover Type N/A Phase / Indoors (Orange) N/A Ground / Indoors (Green) N/A Phase & Ground / Outdoors UV Stable (Black) N/A Phase & Ground/ Indoors & Outdoors (Red) N/A Phase / Indoors (Orange)
Weight N/A 0.81 lb/ft N/A 0.81 lb/ft N/A 0.81 lb/ft N/A 0.81 lb/ft N/A 1.31 lb/ft
Length N/A 5 to 29 ft
Cross Sectional Area N/A 0.45 in² N/A 0.45 in² N/A 0.45 in² N/A 0.45 in² N/A 0.70 in²
Maximum System Voltage AC or DC (Per UL Listing) N/A 600 V N/A 600 V N/A 600 V N/A 600 V N/A 4160 V600 V
Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft N/A 3.27 x 10-5 c/ft N/A 3.27 x 10-5 c/ft N/A 3.27 x 10-5 c/ft N/A 2.11 x 10-5 c/ft
Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft N/A 5.40 x 10-5 c/ft N/A 5.40 x 10-5 c/ft N/A 5.40 x 10-5 c/ft N/A 4.21 x 10-5 c/ft
Support Spacing N/A 5 ft N/A 5 ft N/A 5 ft N/A 5 ft N/A 7.5 ft
Spacing between Conductors N/A 3.0 in
Minimum Bending Radius N/A 8 ft N/A 8 ft N/A 8 ft N/A 8 ft N/A 10 ft
Normal Ambient N/A -40 to 104 ºF N/A -40 to 104 ºF N/A -40 to 104 ºF N/A -40 to 200 ºF N/A -40 to 104 ºF
Dielectric Strength N/A 450 V/mil N/A 450 V/mil N/A 450 V/mil N/A 600 V/mil N/A 450 V/mil
Volume Resistivity N/A >1012 Ω/mil N/A >1012 Ω/mil N/A >1012 Ω/mil N/A >1013 Ω/mil N/A >1012 Ω/mil
Flame Test N/A Self Extinguishing
Specific Density N/A 1.5 g/cm³ N/A 1.5 g/cm³ N/A 1.5 g/cm³ N/A 1.15 g/cm³ N/A 1.5 g/cm³
Available Accessories N/A Pick-up Guides for discontinuous systems Thermostatically controlled heater wire system, for ice and snow environments Transfer Caps for switches Vertical and horizontal curves N/A Pick-up Guides for discontinuous systems Thermostatically controlled heater wire system, for ice and snow environments Transfer Caps for switches Vertical and horizontal curves N/A Pick-up Guides for discontinuous systems Thermostatically controlled heater wire system, for ice and snow environments Transfer Caps for switches Vertical and horizontal curves N/A Pick-up Guides for discontinuous systems Thermostatically controlled heater wire system, for ice and snow environments Transfer Caps for switches Vertical and horizontal curves N/A Pick-up Guides for discontinuous systems Transfer Caps for switches Vertical and horizontal curves