DURA-COAT Conductor Bar Cut Lengths with Splice Installed
Conductor Bars
for highly corrosive environments
Item # |
Amperage Rating |
Material |
Cover Type |
Weight |
Cross Sectional Area |
Resistance R (for DC) at 20º C |
Phase Corrected Impedance Z at 20º C |
---|---|---|---|---|---|---|---|
39747-J 39747-J/Asset/Hevidura-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
51861-J 51861-J/Asset/Hevidura-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A PVC | Cover Type N/A Ground / Indoors (Green) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
51367-J 51367-J/Asset/Hevidura-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
51383-J 51383-J/Asset/Hevidura-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
51372-J 51372-J/Asset/Hevidura-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
51862-J 51862-J/Asset/Hevidura-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A PVC | Cover Type N/A Ground / Indoors (Green) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
51376-J 51376-J/Asset/Hevidura-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
51374-J 51374-J/Asset/Hevidura-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
51377-J 51377-J/Asset/Hevidura-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
51381-J 51381-J/Asset/Hevidura-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
51379-J 51379-J/Asset/Hevidura-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
51382-J 51382-J/Asset/Hevidura-Bar1500A.jpg | Amperage Rating N/A 1500 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 3.6 lb/ft | Cross Sectional Area N/A 2.29 in² | Resistance R (for DC) at 20º C N/A 0.64 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 2.28 x 10-5 c/ft |
50230-J 50230-J/Asset/Hevidura-Bar1500A.jpg | Amperage Rating N/A 1500 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 3.6 lb/ft | Cross Sectional Area N/A 2.29 in² | Resistance R (for DC) at 20º C N/A 0.64 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 2.28 x 10-5 c/ft |
39430-J 39430-J/Asset/Hevidura-Bar1500A.jpg | Amperage Rating N/A 1500 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 3.6 lb/ft | Cross Sectional Area N/A 2.29 in² | Resistance R (for DC) at 20º C N/A 0.64 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 2.28 x 10-5 c/ft |