Products Catalog
WCB elements are disc type, externally cooled units. They are designed to absorb and dissipate the thermal loads associated with the most severe clutch and brake applications. The WCB friction couple was developed specifically for continuous slip service and has a dynamic coefficient of friction that is greater than its static coefficient of friction. Also available, special high coefficient linings, which provide 50% higher torque than standard friction linings and provide a 1:1 dynamic to static torque ratio. Element construction and operation is illustrated. Pressurizing the cylinder causes the piston to clamp the friction disc between the water jackets. Heat generated at the friction interface is quickly transferred to the circulating coolant. Element sizes are indicated by the number of friction discs and the disc diameter in inches. For instance, size 224WCB has two (2) friction discs 24 inches in diameter.
Unit of Measure

Specifications

Size

N/A 124WCB

Dimension D24

N/A 1.06 in27 mm

Dimension D25

N/A 1.75 in44 mm

Dimension D29

N/A 0.250 in6.4 mm

Dimension D46

N/A 1.38 in35 mm

Dimension D43

N/A 4.13 in105 mm
Dimension G1 N/A 29.998 in761.9 mm

Number of Bolt Holes H3

N/A 12

Bolt Hole Size H3

N/A 1 1/8-7 in1 1/8-7 mm
Bolt Circle Diameter H32 N/A 27.875 in708.0 mm

Dimension H10

N/A 12.75 in324 mm
Dimension H133 N/A 24.375 in619.1 mm

Dimension J1

N/A 11.50 in292 mm
Dimension J24 N/A 30.62 in778 mm

Number H4

N/A 6

Size H4

N/A 3/8-16 in3/8-16 mm

Bolt Circle H4

N/A 12.250 in311.2 mm

Large Piston Inlet Thread Size O2

N/A 1/2-14 in1/2-14 mm

Large Piston Inlet Bolt Circle Diameter

N/A 20.500 in521 mm

Small Piston Inlet Thread Size O2

N/A 3/8-18 in3/8-18 mm

Small Piston Inlet Bolt Circle Diameter

N/A 14.500 in368 mm

Minimum Bore Size

N/A 3.75 in95 mm

Maximum Bore Size

N/A 7.25 in184 mm

Dimension D

N/A 11.00 in279 mm

Dimension D1

N/A 3.50 in89 mm

Dimension D2

N/A 9.26 in235 mm
Number of Coolant Ports (O)5 N/A 4
Coolant Port Thread Size6 N/A 3/4 SAE ORB

Gear Part Number

N/A 411672
Dynamic Torque Rating7 N/A 100000 lb-in @ 80 psi 11298 Nm @ 5.5 bar

Dynamic Torque Rating - Large Piston Only

N/A 8135 Nm @ 5.5 bar

Dynamic Torque Rating - Small Piston Only

N/A 3051 Nm @ 5.5 bar
Thermal Rating8 N/A 270 hp201.3 kW
Water Flow9 N/A 27 gpm102.2 dm³/min
Maximum Slip Speed10 N/A 715 rpm
Maximum Freewheeling Speed11 N/A 1200

Housing (Weight)

N/A 445 lb202 kg

Disc & Gear (Weight)

N/A 208 94

Housing (Inertia)

N/A 622 lb·ft²26.21 kg·m²

Disc & Gear (Inertia)

N/A 3.29 78

Water Volume

N/A 160 in³2.6 dm³

Manufacturer

N/A Eaton-Airflex

Actuation

N/A Air Applied

General Description

N/A Element construction and operation is illustrated. Pressurizing the cylinder causes the piston to clamp the friction disc between the water jackets. Heat generated at the friction interface is quickly transferred to the circulating coolant.

Element sizes are indicated by the number of friction discs and the disc diameter in inches. For instance, size 224WCB has two (2) friction discs 24 inches in diameter.

Where Used

N/A

  • Drilling rigs
  • Dynamometer
  • Logging equipment
  • Marine mooring systems
  • Slip clutches
  • Tension brakes
  • Unwind stands

Features

N/A Patented piston design
Single or dual piston provides wider range of applied tension with greater control.

Drop in powerhead package
Standard single piston elements can be retrofitted with a dual piston powerhead to provide increased control.

Split wear spacers
The split wear spacers allow for wear adjustment without disassembly of the brake to minimize downtime and maintenance costs.

Unique friction couple
A specially formulated friction material, interfacing with a copper alloy surface, eliminates the stick-slip characteristic associated with ordinary frictional devices.

Rapid heat dissipation
The copper interface conducts heat rapidly to the circulating coolant.

Open or closed loop coolant systems
The element works equally well with open or closed loop circulating systems. On mobile equipment, the engine’s cooling system can be tapped to provide coolant to the element.

Optional corrosion protection
For marine environment applications, protective coatings are available to minimize corrosion

Note

N/A Basic part number only.Order gear separately.
Some high torque applications of three or four disc elements require additional torsonial support on the cylinder end of the unit. Contact your Airflex representative for more details.

  • 1 Tolerance Sizes 8WCB thru 24WCB
    +0.000/-0.003 (+0.00/-0.08)
    36WCB +0.000/-0.005 (+0.00/-0.13)
    48WCB +0.000/-0.005 (+0.00/-0.13)
  • 2 American National Standard for Unified Screw Threads
  • 3 Tolerance +0.003/-0.000 in.(0.08/-0.00 mm)
  • 4 Maximum diameter of "as cast" surfaces
  • 5 American National Pipe Thread
  • 6 American National Pipe Thread
  • 7 Exact torque rating is dependent upon applied pressure. Maximum allowable pressure is 150 psi (10.3 bar).
  • 8 Exact torque rating is dependent upon applied pressure. Maximum allowable pressure is 150 psi (10,3 bar).maximum allowable outlettemperatures are 150ºF (65ºC) for fresh water; 165ºF (74ºC) for 70/30 and 60/40 water glycol mixes; and 170ºF (77ºC) for 50/50 water glycol mixes.
  • 9 To insure proper cooling, inlet port must be at the six o’clock position. Flow rates shown are for fresh water, flow rates for water glycol mixes must increase to achieve the ratings in the Thermal Rating column. Maximum allowable inlet pressure - 65 psi
  • 10 Based upon a continuous slip velocity of 4500 fpm (22.9 mps).
  • 11 Maximum freewheeling velocity is 7500 fpm (38.1 mps).