Specifications
Size |
N/A 76VC1600 |
Torque Rating (75 psi/5.5 bar) |
N/A 7300000 lb·in827050 Nm |
Maximum Speed1 | N/A 416 rpm |
Centrifugal Loss Cs |
N/A 16.66 E-06 bar/rpm2 241 E-06 psi/rpm2 |
Inertia |
N/A 72940 lb·ft²3074 kg·m² |
Weight |
N/A 5970 lb2705 kg |
Friction Area |
N/A 6940 in²45150 cm² |
New Friction |
N/A 0.66 in17 mm |
Worn Lining Thickness |
N/A 0.30 in8 mm |
Air Tube Cavity |
N/A 4800 in³79 dm³ |
Minimum Drum Diameter2 | N/A 75.75 in1924 mm |
Dimension D2 |
N/A 37.00 in940 mm |
Dimension D3 |
N/A 0.88 in22 mm |
Dimension D25 |
N/A 1.38 in35 mm |
Dimension G |
N/A 92.123 in2339.9 mm |
Tolerance for Sizes (G) |
N/A +0.000/-0.005 in+0.00/-0.13 mm |
Dimension H2 |
N/A 89.625 in2276.5 mm |
Dimension H6 |
N/A 76.72 in1948 mm |
Dimension H7 |
N/A 88.38 in2245 mm |
Number of Hole L |
N/A 48 |
Tolerance for L |
N/A +0.005/-0.000 in+0.13/-0.00 mm |
Dimension L Diameter |
N/A 1.312 in33.3 mm |
O3 Number |
N/A 4 |
Size O3 |
N/A 0.88 in22 mm |
Angle Q |
N/A 3.75 º |
Dimension V |
N/A 1.25 in32 mm |
W Number |
N/A 50 |
Friction Shoe Width (W) |
N/A 34.50 in876 mm |
Manufacturer |
N/A Eaton-Airflex |
Actuation |
N/A Air Applied |
General Description
N/A
VC design and construction is different from the CB and CM elements in that the torque is transmitted by torque bars rather than the sidewalls of the actuating tube. The loose actuating tube is contained within a housing formed by a rim and two side plates. and is replaceable. The torque bars, which are held in position by the side plates, pass through cavities in the backing plates of the friction shoes. Pressurizing the actuating tube forces the friction shoes to engage around a cylindrical drum. Leaf springs in the torque bar cavities of the backing plates retract the friction shoes when the actuating tube pressure is released. Element torque capacity is dependent upon the applied pressure and rotating speed. Catalog ratings are given at 75 psi (5.2 bar) and zero rpm. Maximum recommended pressure is 125 psi (8.6 bar). Adjustment for
pressure and speed is explained under Selection Procedure. |
Features
N/A
Ventilated Construction |
- 1 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
- 2 Drum contact with worn shoes.