Roll formed of 1/32" material
The equivalent rectangle for all conductors is 1" x 1/4". Supports are required at intervals of: 3' on curves, 3'-4" for lateral mount, 5' standard.
The solid copper conductors are supplied in 20' lengths, covered, with connector clamp and case. Conductor bar and covers may be ordered separately for replacement purposes.
The equivalent rectangle for all conductors is 1" x 1/4". Supports are required at intervals of: 3' on curves, 3'-4" for lateral mount, 5' standard.
The solid copper conductors are supplied in 20' lengths, covered, with connector clamp and case. Conductor bar and covers may be ordered separately for replacement purposes.
Item # |
Material |
Cover Type |
Weight |
Length |
Resistance R (for DC) at 20º C |
Normal Ambient |
---|---|---|---|---|---|---|
11016 | N/A Solid Copper | N/A Rigid PVC | N/A 23.6 lb0.16 lb/ft | N/A 20 ft | N/A 40 µΩ/ft | N/A -10 to 160 ºF |
11017 | N/A Solid Copper | N/A Rigid PVC | N/A 11.8 lb0.16 lb/ft | N/A 5 ft | N/A 40 µΩ/ft | N/A -10 to 160 ºF |
11035 | N/A Solid Copper | N/A Medium Heat | N/A 22.1 lb0.16 lb/ft | N/A 20 ft | N/A 40 µΩ/ft | N/A -25 to 250 ºF |
11036 | N/A Solid Copper | N/A Medium Heat | N/A 11.0 lb0.16 lb/ft | N/A 5 ft | N/A 40 µΩ/ft | N/A -25 to 250 ºF |
11054 | N/A Solid Copper | N/A High Heat | N/A 24.6 lb0.16 lb/ft | N/A 20 ft | N/A 40 µΩ/ft | N/A -60 to 400 ºF |
11055 | N/A Solid Copper | N/A High Heat | N/A 12.3 lb0.16 lb/ft | N/A 5 ft | N/A 40 µΩ/ft | N/A -60 to 400 ºF |