Standard Conductor Bar Cut Lengths for Hevi-Bar II Conductor Bar
Conductor Bars
Item # |
Amperage Rating |
Material |
Cover Type |
Weight |
Cross Sectional Area |
Resistance R (for DC) at 20º C |
Phase Corrected Impedance Z at 20º C |
---|---|---|---|---|---|---|---|
27583 27583/Asset/Heviconductor-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
50260 50260/Asset/Heviconductor-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A PVC | Cover Type N/A Ground / Indoors (Green) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
38926 38926/Asset/Heviconductor-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
39225 39225/Asset/Heviconductor-Bar500A.jpg | Amperage Rating N/A 500 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 0.81 lb/ft | Cross Sectional Area N/A 0.45 in² | Resistance R (for DC) at 20º C N/A 3.27 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 5.40 x 10-5 c/ft |
24529 24529/Asset/Heviconductor-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
51369 51369/Asset/Heviconductor-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A PVC | Cover Type N/A Ground / Indoors (Green) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
38936 38936/Asset/Heviconductor-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
51371 51371/Asset/Heviconductor-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
24555 24555/Asset/Heviconductor-Bar700A.jpg | Amperage Rating N/A 700 A | Material N/A Fiberglass Reinforced Polyester | Cover Type N/A Phase & Ground / Indoors (Orange) | Weight N/A 1.31 lb/ft | Cross Sectional Area N/A 0.70 in² | Resistance R (for DC) at 20º C N/A 2.11 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 4.21 x 10-5 c/ft |
23503 23503/Asset/Heviconductor-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
38938 38938/Asset/Heviconductor-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
51408 51408/Asset/Heviconductor-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
23511 23511/Asset/Heviconductor-Bar1000A.jpg | Amperage Rating N/A 1000 A | Material N/A Fiberglass Reinforced Polyester | Cover Type N/A Phase & Ground / Indoors (Orange) | Weight N/A 2.8 lb/ft | Cross Sectional Area N/A 1.05 in² | Resistance R (for DC) at 20º C N/A 1.41 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 3.39 x 10-5 c/ft |
24003 24003/Asset/Heviconductor-Bar1500A.jpg | Amperage Rating N/A 1500 A | Material N/A PVC | Cover Type N/A Phase / Indoors (Orange) | Weight N/A 3.6 lb/ft | Cross Sectional Area N/A 2.29 in² | Resistance R (for DC) at 20º C N/A 0.64 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 2.28 x 10-5 c/ft |
38944 38944/Asset/Heviconductor-Bar1500A.jpg | Amperage Rating N/A 1500 A | Material N/A PVC | Cover Type N/A Phase & Ground / Outdoors UV Stable (Black) | Weight N/A 3.6 lb/ft | Cross Sectional Area N/A 2.29 in² | Resistance R (for DC) at 20º C N/A 0.64 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 2.28 x 10-5 c/ft |
39295 39295/Asset/Heviconductor-Bar1500A.jpg | Amperage Rating N/A 1500 A | Material N/A Polycarbonate | Cover Type N/A Phase & Ground/ Indoors & Outdoors (Red) | Weight N/A 3.6 lb/ft | Cross Sectional Area N/A 2.29 in² | Resistance R (for DC) at 20º C N/A 0.64 x 10-5 c/ft | Phase Corrected Impedance Z at 20º C N/A 2.28 x 10-5 c/ft |