8CB250 Element
Form CB-401
Form CB-401
Unit of Measure
Specifications
Size |
N/A 8CB250 |
Torque Rating (75 psi/5.5 bar)1 | N/A 4290 lb·in485 Nm |
Maximum Speed2 | N/A 1800 rpm |
Centrifugal Loss Constant Cs |
N/A 0.48 E-06 bar/rpm2 7.0 E-06 psi/rpm2 |
Inertia |
N/A 2.0 lb·ft²0.08 kg·m² |
Weight |
N/A 9 lb4.1 kg |
Friction Area |
N/A 61 in²393.5 cm² |
New Friction Lining Thickness |
N/A 0.12 in3 mm |
Worn Friction Lining Thickness |
N/A 0.06 in2 mm |
Air Tube Cavity3 | N/A 30 in³0.49 dm³ |
Minimum Drum Diameter |
N/A 7.90 in201 mm |
Dimension D2 |
N/A 3.44 in87 mm |
Dimension D24 |
N/A 1.91 in48 mm |
Dimension D25 |
N/A 0.09 in2 mm |
Dimension G4 | N/A 12.875 in327 mm |
Dimension G1 |
N/A 11.19 in284 mm |
Dimension H2 |
N/A 12.125 in308 mm |
Dimension H6 |
N/A 8.16 in207 mm |
Dimension H7 |
N/A 12.13 in308 mm |
Number of Mounting Holes |
N/A 8 |
Bolt Hole Size L |
N/A 0.38 in10 mm |
Dimension O3 |
N/A 0.31 in8 mm |
Air Inlet Thread |
N/A 3/8-18 |
Angle Q |
N/A 22.500 º |
Dimension V |
N/A 0.56 in14 mm |
Number of Friction Shoes |
N/A 8 |
Friction Shoe Width (W) |
N/A 2.50 in64 mm |
Manufacturer |
N/A Airflex |
- 1 Dynamic torque shown, static torque approximately 25% greater. Torque in each application is dependent upon air pressure and speed.
- 2 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
- 3 Drum contact with worn shoes.
-
4 Tolerance for sizes:
3 thru 5
+0.000/-0.003 in (+0.00/-0.08 mm)
6 and larger
+0.000/-0.005 in (+0.00/-0.13 mm)