Specifications
Size |
N/A 11.5VC500 |
Torque Rating (75 psi/5.5 bar) |
N/A 54000 lb·in6100 Nm |
Maximum Speed1 | N/A 1800 rpm |
Centrifugal Loss Cs |
N/A 1.59 E-06 bar/rpm2 23 E-06 psi/rpm2 |
Inertia |
N/A 86 lb·ft²3.61 kg·m² |
Weight |
N/A 197 lb89 kg |
Friction Area |
N/A 332 in²2141 cm² |
New Friction |
N/A 0.32 in8 mm |
Worn Lining Thickness |
N/A 0.16 in4 mm |
Air Tube Cavity2 | N/A 140 in³2.3 dm³ |
Minimum Drum Diameter |
N/A 11.41 in11.41 mm |
Dimension D2 |
N/A 12.75 in324 mm |
Dimension D3 |
N/A 0.23 in6 mm |
Dimension D25 |
N/A 0.56 in14 mm |
Dimension G |
N/A 19.625 in498.5 mm |
Tolerance for Sizes (G) |
N/A +0.000/-0.005 in+0.00/-0.13 mm |
Dimension H2 |
N/A 18.875 in479.4 mm |
Dimension H6 |
N/A 11.63 in295 mm |
Dimension H7 |
N/A 18.88 in479 mm |
Number of Hole L |
N/A 16 |
Dimension L Diameter |
N/A 0.375 in9.5 mm |
Tolerance for L |
N/A +0.005/-0.000 in+0.13/-0.00 mm |
O3 Number |
N/A 2 |
Size O3 |
N/A 0.31 in8 mm |
Angle Q |
N/A 11.250 º |
Dimension V |
N/A 0.56 in14 mm |
Number of Friction Shoes |
N/A 16 |
Friction Shoe Width (W) |
N/A 11.63 in295 mm |
Manufacturer |
N/A Eaton-Airflex |
Actuation |
N/A Air Applied |
General Description
N/A
VC design and construction is different from the CB and CM elements in that the torque is transmitted by torque bars rather than the sidewalls of the actuating tube. The loose actuating tube is contained within a housing formed by a rim and two side plates. and is replaceable. The torque bars, which are held in position by the side plates, pass through cavities in the backing plates of the friction shoes. Pressurizing the actuating tube forces the friction shoes to engage around a cylindrical drum. Leaf springs in the torque bar cavities of the backing plates retract the friction shoes when the actuating tube pressure is released. Element torque capacity is dependent upon the applied pressure and rotating speed. Catalog ratings are given at 75 psi (5.2 bar) and zero rpm. Maximum recommended pressure is 125 psi (8.6 bar). Adjustment for
pressure and speed is explained under Selection Procedure. |
Features
N/A
Ventilated Construction |
- 1 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
- 2 Drum contact with worn shoes.