Specifications
Size |
N/A 20VC600 |
Torque Rating (75 psi/5.5 bar) |
N/A 186000 lb·in21010 Nm |
Maximum Speed1 | N/A 1200 rpm |
Centrifugal Loss Cs |
N/A 2.76 E-06 bar/rpm2 40 E-06 psi/rpm2 |
Inertia |
N/A 386 lb·ft²16.21 kg·m² |
Weight |
N/A 363 lb164 kg |
Friction Area |
N/A 760 in²4902 cm² |
New Friction |
N/A 0.32 in8 mm |
Worn Lining Thickness |
N/A 0.16 in4 mm |
Air Tube Cavity2 | N/A 280 in³4.59 dm³ |
Minimum Drum Diameter |
N/A 19.88 in19.88 mm |
Dimension D2 |
N/A 15.19 in386 mm |
Dimension D3 |
N/A 0.31 in8 mm |
Dimension D25 |
N/A 0.56 in14 mm |
Dimension G |
N/A 29.500 in749.3 mm |
Tolerance for Sizes (G) |
N/A +0.000/-0.005 in+0.00/-0.13 mm |
Dimension H2 |
N/A 28.375 in720.7 mm |
Dimension H6 |
N/A 20.22 in514 mm |
Dimension H7 |
N/A 28.38 in721 mm |
Number of Hole L |
N/A 12 |
Dimension L Diameter |
N/A 0.500 in12.7 mm |
Tolerance for L |
N/A +0.005/-0.000 in+0.13/-0.00 mm |
O3 Number |
N/A 4 |
Size O3 |
N/A 0.38 in10 mm |
Angle Q |
N/A 15.000 º |
Dimension V |
N/A 0.69 in17 mm |
Number of Friction Shoes |
N/A 20 |
Friction Shoe Width (W) |
N/A 13.81 in351 mm |
Manufacturer |
N/A Eaton-Airflex |
Actuation |
N/A Air Applied |
General Description
N/A
VC design and construction is different from the CB and CM elements in that the torque is transmitted by torque bars rather than the sidewalls of the actuating tube. The loose actuating tube is contained within a housing formed by a rim and two side plates. and is replaceable. The torque bars, which are held in position by the side plates, pass through cavities in the backing plates of the friction shoes. Pressurizing the actuating tube forces the friction shoes to engage around a cylindrical drum. Leaf springs in the torque bar cavities of the backing plates retract the friction shoes when the actuating tube pressure is released. Element torque capacity is dependent upon the applied pressure and rotating speed. Catalog ratings are given at 75 psi (5.2 bar) and zero rpm. Maximum recommended pressure is 125 psi (8.6 bar). Adjustment for
pressure and speed is explained under Selection Procedure. |
Features
N/A
Ventilated Construction |
- 1 Maximum rpm is dependent upon operating conditions and varies for each application. Consult factory for applications exceeding these speeds.
- 2 Drum contact with worn shoes.