Size |
N/A 60VC1600 |
Torque Rating (75 psi/5.5 bar) |
N/A 2183000 lb·in246645 Nm |
Maximum Speed1 | N/A 520 rpm |
Centrifugal Loss Cs |
N/A 10.01 E-06 bar/rpm2 145 E-06 psi/rpm2 |
WK2 |
N/A 20532 lb·ft² |
Dimension J |
N/A 852.3 kg·m² |
Weight |
N/A 2374 lb1077 kg |
Friction Area |
N/A 2800 in²18060 cm² |
New Friction |
N/A 0.66 in17 mm |
Worn Lining Thickness |
N/A 0.30 in8 mm |
Air Tube Cavity2 | N/A 2350 in³38.5 dm³ |
Minimum Drum Diameter |
N/A 59.75 in1518 mm |
Dimension D2 |
N/A 18.50 in470 mm |
Dimension D3 |
N/A 0.61 in15 mm |
Dimension D24 |
N/A 9.25 in235 mm |
Dimension D25 |
N/A 1.38 in35 mm |
Dimension G |
N/A 77.000 in1955.8 mm |
Tolerance for Sizes (G) |
N/A +0.000/-0.010 in+0.00/-0.25 mm |
Dimension H2 |
N/A 75.000 in1905 mm |
Dimension H6 |
N/A 60.43 in1535 mm |
Dimension H7 |
N/A 74.25 in1886 mm |
Number of Hole L |
N/A 36 |
Dimension L Diameter |
N/A 1.000 in25.4 mm |
Tolerance for L |
N/A +0.005/-0.000 in+0.13/-0.00 mm |
Dimension O3 |
N/A 0.88 in22 mm |
O4 Number |
N/A 4 |
Size O4 |
N/A 1-11 1/2 NPT |
Angle Q |
N/A 5.00 º |
Dimension V |
N/A 1.25 in32 mm |
W Number |
N/A 20 |
Friction Shoe Width (W) |
N/A 16 in406 mm |
Manufacturer |
N/A Eaton-Airflex |
Actuation |
N/A Air Applied |
N/A
VC design and construction is different from the CB and CM elements in that the torque is transmitted by torque bars rather than the sidewalls of the actuating tube. The loose actuating tube is contained within a housing formed by a rim and two side plates. and is replaceable. The torque bars, which are held in position by the side plates, pass through cavities in the backing plates of the friction shoes. Pressurizing the actuating tube forces the friction shoes to engage around a cylindrical drum. Leaf springs in the torque bar cavities of the backing plates retract the friction shoes when the actuating tube pressure is released. Element torque capacity is dependent upon the applied pressure and rotating speed. Catalog ratings are given at 75 psi (5.2 bar) and zero rpm. Maximum recommended pressure is 125 psi (8.6 bar). Adjustment for
pressure and speed is explained under Selection Procedure. |
N/A
Ventilated Construction |